BITUVER XB-10 membranes are realized with plastomeric (BPP) compound that reaches –10°C cold flexibility.
BITUVER XB-10 membranes are realized with plastomeric (BPP) compound that reaches –10°C cold flexibility.
The product has a good mechanical resistance and high dimensional stability.

BITUVER XB-10 is also available in the “TEX” version with “DECOTEX” treatment, consisting in the application on the upper face of a special black polypropylene tissue.
Bituver XB-10 MINERAL è is available with natural or colored slates.

Advantages

  • Wide range of versions
  • Easy installation

Variants Details

Technical Data Standard Reference Bituver XB-10 Toll.
Cold flexibility UNI EN 1109 – 10°C
Flow resistance EN 1110 120°C
Flow resistance
after ageing
UNI EN 1296
UNI EN 1110
110°C – 10°C
Tensile strength
at breaking L/T
UNI EN 12311-1 400/250 N
/50 mm
– 20%
Vapour permeability UNI EN 1931 μ 20.000
 
Dimensions Reinforcement Thickness
weight/m2
m²/pallet
Bituver XB-10
4 mm P
Polyester 4 mm 230
Bituver XB-10
TEX 4 mm P
Polyester 4 mm 230
Bituver XB-10
Mineral 4 kg P
Polyester 4 kg 250
Bituver XB-10
Mineral 4,5 kg P
Polyester 4,5 kg 230
It is advisable to keep the rolls in warehouse, not exposed to the sun rays and at a higher temperature than +5°C. Keep the rolls in the upright position. If possible, avoid stacking pallets, especially with slated membranes. It is advisable to use the product within 2/3 months from delivery.
 
Main Uses Bituver XB-10 P Bituver X-10 MINERAL P
Base layer X  
Middle layer X  
Top layer X (4 mm)* X
Foundation X  
Earth retention X  
Under tiles   X
*  4mm with protective paint

Miscellaneous

APPLICATION

  • Use Personal Protective Equipment as requested by law;
  • Clean properly the surface on which membranes has to be applied;
  • The treatment of the application surface with Bituver ECOPRIVER water based bituminous primer is suggested;
  • BITUVER XB-10 is meant to be applied by flame with a gas propane blow torch by heating the lower face, covered with a special termofusibile film;
  • Apply between +5° C and + 35° C.